Radiology Room |
Ultrasound Room |
Surgery Room |
Laboratory Room |
Comprehensive Room |
Pediatrics Room |
Dental Room |
Medical operation instruments |
Hospital Furniture |
Medical supplies |
30-500MA 、HF、DENTAL X RAY 、C-ARM
Mobile High Frequency Medical C-arm X-ray Machine JY-A28
Mobile High frequency Medical C-arm X-ray Machine
C-arm X-ray Machine Introduction:
The clinical applications of this C-arm X-ray machine include orthopedics (arthroplasty, joint nailing, joint fluoroscopy, restoration and fixation for bone injury in emergency), radiology (abdominal organ angiography, gastrointestinal fluoroscopy), gynecology (uterus angiography), urology (kidney and bladder angiography), surgery (pacemaker implantation, peripheral vascular examination, etc.) and so on.
C-arm X-ray Machine Introduction:
The clinical applications of this C-arm X-ray machine include orthopedics (arthroplasty, joint nailing, joint fluoroscopy, restoration and fixation for bone injury in emergency), radiology (abdominal organ angiography, gastrointestinal fluoroscopy), gynecology (uterus angiography), urology (kidney and bladder angiography), surgery (pacemaker implantation, peripheral vascular examination, etc.) and so on.
Key Features of C-arm X-ray Machine:
1. Adopts the true digital high frequency host, gets the clearest and richest image with minimum dose, greatly reduces the potential harm of x-ray to clinicians and patients.
2. The unique double displays make operation intuitive, easy and reliable.
3. The vertical and horizontal movements and rotation of C-arm are all electric maneuvered.
4. Micro-computer based controller features with failure self-diagnostic function, easy maintenance.
5. Digital interfaces optionally equip with picture collection & storage workstation, directly upgrade the digital image system, to provide a short cut for your heavy file management.
Upgraded Digital Image System of C-arm X-ray Machine:
1. Up to 100,000 static images stored in hard disk
2. Multi-image simultaneously display
3. Image processing functions: rotation, overturn lightness and contrast adjustment
4. Diagnostic report by laser printer
Technical Data:
1. Adopts the true digital high frequency host, gets the clearest and richest image with minimum dose, greatly reduces the potential harm of x-ray to clinicians and patients.
2. The unique double displays make operation intuitive, easy and reliable.
3. The vertical and horizontal movements and rotation of C-arm are all electric maneuvered.
4. Micro-computer based controller features with failure self-diagnostic function, easy maintenance.
5. Digital interfaces optionally equip with picture collection & storage workstation, directly upgrade the digital image system, to provide a short cut for your heavy file management.
Upgraded Digital Image System of C-arm X-ray Machine:
1. Up to 100,000 static images stored in hard disk
2. Multi-image simultaneously display
3. Image processing functions: rotation, overturn lightness and contrast adjustment
4. Diagnostic report by laser printer
Technical Data:
Generator power/Frequency
|
3.5kw/40KHz
|
5kw/40KHz
|
Radiography KV
|
40-110KV
|
40-120KV
|
Radiography mA
|
30-70mA
|
24-70mA
|
Fluoroscopy KV
|
40-110KV
|
40-120KV
|
Fluoroscopy mA
|
0.1-5mA
|
0.1-5mA
|
Pulse fluoroscopy
|
0.1-8mA
|
0.1-8mA
|
Focus size
|
0.6×1.5mm
|
0.3×0.6mm
|
Stationary anode
|
Rotation anode
|
|
Anode heat capacity
|
30KJ(40kHU)
|
150KJ(200kHU)
|
Heat capacity of
|
500KJ(667kHU)
|
600KJ(800kHU)
|
Collimator
|
Iris, auto-tracking, variable visual field, double leaf
|
|
Focus-to-image intensifier distance(SID)
|
1000mm
|
1000mm
|
C-arm depth
|
730mm
|
730mm
|
C-arm open
|
815mm
|
815mm
|
C-arm arc glide with full balance
|
115°
|
115°
|
C-arm rotation(motored)
|
±180°
|
±180°
|
Upward and downward movement(motored)
|
400mm
|
400mm
|
Forward and backward movement(motored)
|
200mm
|
200mm
|
Horizontal swing angle
|
±12.5°
|
±12.5°
|
Image intensifier
|
9" metal screen intensifier
|
|
Camera
|
High speed CCD camera
|
|
Monitor
|
14" high resolution monitor
|
|
Panel
|
Two operation panels, automatic display error codes
|
|
Image memory
|
Store 8 images, freeze the last image, multilevel denoise, double displays in one screen
|
|
Supply power
|
220V,50Hz,20A
|
|
Power capacitor
|
4KVA
|