10-100MA x ray machine
100mA Photography X Ray Machine JY-A1
100mA photography x ray machine
General radiography, Filter-ray-filter radiograph
Unit Configuration
Control, HT generator unit, Ht cable, X-ray tube unit, Radiographic table-X-ray source column, Collimator
Function
This photography x ray can used for general radiography, Bucky radiography of body’s head, chest, foot and hand, bones in lying
Feature
1. meter-indicating
2. single-table single tube
3. single-phase, full wave rectification
4. stationary anode x-ray tube assembly
5. X-ray tube filament s voltage regulator, space charge compensator
6. Radiograph plain table wimple structure and easy assembling
Min Technical Indexes
General radiography, Filter-ray-filter radiograph
Unit Configuration
Control, HT generator unit, Ht cable, X-ray tube unit, Radiographic table-X-ray source column, Collimator
Function
This photography x ray can used for general radiography, Bucky radiography of body’s head, chest, foot and hand, bones in lying
Feature
1. meter-indicating
2. single-table single tube
3. single-phase, full wave rectification
4. stationary anode x-ray tube assembly
5. X-ray tube filament s voltage regulator, space charge compensator
6. Radiograph plain table wimple structure and easy assembling
Min Technical Indexes
Item
|
Contents
|
Index
|
Demand of power supply
|
Capacity
|
Two-phase 30KVA
|
Voltage, Frequency
|
380V/220V ±10%50HZ ±0.5Hz
|
|
Intemal resistance
|
2Ω(380V) 0.6 Ω(220V)
|
|
power supply
|
Adjustable range
|
380±10% at220V being adjustable continuously
|
Radiograph
|
Voltage
|
50-90KV
|
Current
|
Small focus: 15mA,Big focus:30mA 60mA 100mA
|
|
Time
|
0.04~6.35s 23grades together grading a according to R10 coefficient
|
|
High-voltage generator
|
Capacity
|
7KVA
|
Max DC output voltage
|
90KV
|
|
Max DC output current
|
100mA
|
|
X-Ray tube
|
Model
|
0XD4-2.9/100
|
Focus
|
Small focus 1.8×1.8mm big focus4.3×4.3mm
|
|
Radiographic table
|
Length×width×height of bed surface
|
2000mm×665mm×700mm
|
Moving range of bed surface
|
640mm in Length,200mm in breadth
|
|
Ray-filter of table
|
Travel in length ≥50mm
|
|
Grid density N=28
|
||
Convergence distance f。=100cm
|
||
Grid ratio r=8
|
||
Column of X-ray tube unit
|
Moving Longitudinally along
|
1000mm or 1800mm
|
Radiographic table
|
||
Distance to friend as moving up and down (along column)
|
650~1800mm
|
|
Rotary around the center of cross arm
|
±180°
|
|
Rotary around the shaft line of X-ray annular tubes
|
-10~60~+120°
|
|
Max size of cassette
|
356mm×432mm(14″×17″)
|