Radiology Room |
Ultrasound Room |
Surgery Room |
Laboratory Room |
Comprehensive Room |
Pediatrics Room |
Dental Room |
Medical operation instruments |
Hospital Furniture |
Medical supplies |
30-500MA 、HF、DENTAL X RAY 、C-ARM
3.8kw portable& high frequency X-ray machine JY-C1
Applications: out relief, orthopedic hospitals, cosmetic facial plastic surgery, ICU ward, emergency department, Technical performance:
1. Integrated with high frequency and high voltage generator, main control system, intelligent computer system, numeric display and beam limited device,
2 it is designed and manufactured precisely and compactly, more flexibly and widely used; Using the technique of inverse converter for HF and computer-controlled closed-loop adjusting System, stable high voltage output is generated and high-quality images can be obtained;
3 Using the buttons of KV and mAs to adjust the photographic parameters, display them on high-brightness LEDs, interlock protection conditions is determined by software, which is convenient for doctors to operate;
4 X-ray Tube is placed in lead cylinder which can effectively shield the gamma leakage and protect environment and operators’ safety;
5 20 / 24 radiographic conditions are preset and can be customized according to user requirements.
6 Manually controlled, controls remotely the double control photography function
7 Photographic time by microcomputer accuracy control, photographic conclusion aft engine automatic time delay 30S, but the active control photography gap, avoids overloading the use, realizes the automatic protection
8 Uses the microcomputer to monitor each kind of breakdown source, once breaks down, microcomputer cut-off all outputs, and demonstrate the breakdown code, the recognition breakdown reason.
9 The X-ray machine is hanging on the support then the rapid development throws according to .
10 The X-ray machine fuselages hangs on the support may control ≥±90° revolving, the X-ray shoe may make 90° the turn over, is advantageous for the different angle to throw illuminates. the arm support may reciprocate that follow-up balanced and has locks installs. stand arm can go up and down, running balance and lock up.
12 X-ray machine fuselage 18.6Kg, carries the transportation to be more convenient. Support 23Kg, the different place migration is more flexible, moves to after rapidly to diagnose and treat the supports may disassemble rapidly fold, puts in the car reserve theater box, makes a house call more convenient
13 Is suitable in each kind of size cartridge.
Main specifications and parameters
|
|
Output
|
100kV
|
Max current
|
32-80 mA
|
Power(max)
|
4kW
|
Exposure Time
|
0.01s~4.0s
|
mAs range
|
0.5mAs~160mAs 46step
|
KV range
|
40kV~100kV 1KV steps 60step
|
Inverter Frequency
|
30kHz
|
Collimator light filed size
|
Max.light field:≤35cm*35cm @65cm SID
|
Min.light field:≤5cm*5cm @100cm SID
|
|
Focal Spot
|
1.5mm
|
Voltage
|
Single Prase AC voltage 220V±10% (50/60±1Hz
|
Power supply capacity
|
≥3.5kVA
|
Electricity protection type
|
Class I, Type B
|
Weight
|
32KG
|