400mA Medical X Ray Machine JY-A15
Specifications
1 400mA x ray machine
2 medical x ray machine
3 400mA medical x ray machine
4 x ray machine
5 double diagnostic table
2 medical x ray machine
3 400mA medical x ray machine
4 x ray machine
5 double diagnostic table
400mA Medical X Ray Machine
1 Equipped with double diagnostic table and x-ray rubes, tube voltage is 125kV, tube currency is 400mA, single direct bridge full-wave commutation.
2 X-ray tube capacity protection, anode starting-up protection and radiograph time-limit protection device semi-conduct controlled, fluoroscopy computed time device, x-ray tube over-hot protecionare provided, ensure x-ray tube run safely long time, improve accuracy of kV mA S.
3 Bigger scope of rotation diagnostic table, movable table muli-item spot-film device, easy to operate, radiation proof, ensure operate and the tested.
Department |
Technology parameters
|
|||
High voltage generator control table and high voltage transform assemble
|
Fluoroscopy
|
Tube currency
|
0.3-5mA continuous currency
|
|
Tube voltage
|
45-110KV continuous voltage
|
|||
Radiography
|
Tube currency
|
50-400mA shift
|
||
Tube voltage
|
45-125KV continuous voltage
|
|||
Exposure time
|
0.03-5s23 shift
|
|||
Power
|
Voltage
|
380V±10%
|
||
Frequency
|
50Hz±1Hz
|
|||
Capacity
|
≥30KVA
|
|||
Inner resistance
|
≤0.3Ω
|
|||
X-ray assembly
|
Type of x-ray
|
XD51-20.40/125
|
||
Focus
|
1×1.2×2 double focal
|
|||
Rated rotate speed of anode
|
2800r/min
|
|||
Changed beam limited device
|
Diagnosis table YS09D
|
Automatic, adjusted field of view
|
||
Radiograph table YS11S
|
Manually adjusted field of view, luminosity≥100LX
|
|||
C15 Diagnostic table
|
Rotate of table
|
-15°~0°~90°automatic
|
||
Moving table
|
Automatic 700mm distance moving lengthways
|
|||
Distance of focal table
|
400mm
|
|||
High of table
|
820mm
|
|||
Spot film device
|
Scope moving
|
Up and down
|
600mm
|
|
Left and right
|
±100mm
|
|||
Forward and backward
|
300mm
|
|||
Way of locking
|
Electromagnetism locking
|
|||
Radiography item
|
5×7,8×10,10×12,11×14
|
|||
CDGI Multi function radiography table
|
Moving table
|
Lengthways
|
±600mm
|
Electromagnetism locking
|
Across
|
±120mm
|
|||
Mobile beam filtration grid
|
Grid density
|
28L/cm
|
||
Grid ratio
|
81
|
|||
Focusing distance
|
100cm
|
|||
Scope of moving
|
≥600mm
|
|||
Radiography item
|
5×7,8×10,10×12,11×14,
|
|||
12×15,14×14,14×17
|
||||
Distance from surface to film
|
75mm
|
|||
Height of bed
|
700mm
|
|||
Moving pillar
|
±180°,per 90°orientation, moving lengthways ≥1500mm
|
|||
Bulb tube
|
Rotate the cross arm±180,ascend $ descend 1100mm
|
Option
LSJ pillar radiography frame |
The scope of ascend and descend
|
1450mm
|
|
The minimum distance from focal spot
|
380mm
|
||
Radiography item
|
8”*10” 10”*12” 11”*14”12”*15”
|
||
14”*14” 14”*17”
|
|||
Fixed beam filtration role
|
Grid density
|
40L/cm
|
|
Grid radio
|
10:01
|
||
Focal distance
|
180cm
|